| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | For Measuring | Sensor Type | Number of Channels | Output | Sensitivity | Current - Sensing | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Qualification | Current - Supply (Max) | Grade | Operating Temperature | Polarization | Mounting Style | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DHR 600 C420TRANSDUCER |
2,234 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Current | - | 600mA | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | - | 30mA | - | -40°C ~ 70°C | Unidirectional | Chassis Mount | - |
|
DHR 400 C10TRANSDUCER |
2,832 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 1 | Voltage | - | 400A | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | - | 30mA | - | -40°C ~ 70°C | Unidirectional | Chassis Mount | - |
|
DHR 600 C5TRANSDUCER |
2,458 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Analog Voltage | - | 600mA | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | - | 30mA | - | -40°C ~ 70°C | Unidirectional | Chassis Mount | - |
|
DHR 300 C10TRANSDUCER |
2,793 |
|
Datasheet |
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Voltage | - | 300A | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | - | 30mA | - | -40°C ~ 70°C | Unidirectional | Chassis Mount | - |
|
LTC 1000-S/SP28TRANSDUCER |
1,594 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | 1000A | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | - | - | -40°C ~ 85°C | Bidirectional | Chassis Mount | - |
|
IVT-S-100-U0-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
2,591 |
|
Datasheet |
IVT-S | Module | Tray | Active | DC | Shunt | - | CAN Bus | - | 100A | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | - | 80mA | - | -40°C ~ 105°C | Bidirectional | Chassis Mount | - |
|
DHR 400 C420TRANSDUCER CURRENT 4-20MA OUT |
3,175 |
|
Datasheet |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-SFC/SP1TRANSDUCER |
3,100 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | 1000A | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | - | - | -40°C ~ 85°C | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP26TRANSDUCER |
4,977 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | 1300A | DC ~ 100kHz | ±0.1% | ±0.8% | ±15V ~ 24V | 1µs | - | - | - | -40°C ~ 70°C | Bidirectional | Chassis Mount | - |
|
CR4120-40SENSOR CURRENT XFMR 40A AC |
2,584 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 40A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-50SENSOR CURRENT XFMR 50A AC |
4,988 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 50A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-10SENSOR CURRENT XFMR 10A AC |
4,192 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 10A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-25SENSOR CURRENT XFMR 25A AC |
4,995 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 25A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-15SENSOR CURRENT XFMR 15A AC |
3,398 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 15A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-20SENSOR CURRENT XFMR 20A AC |
1,005 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 20A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-150SENSOR CURRENT XFMR 150A AC |
1,832 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 150A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
CR4120-5SENSOR CURRENT XFMR 5A AC |
1,146 |
|
Datasheet |
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | 5A | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | - | 40mA | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel | - |
|
LF 2010-S/SP33TRANSDUCER |
3,236 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 1 | Current | 0.2mA/A | 2000A | DC ~ 150kHz | ±0.1% | ±0.3% | ±14.25V ~ 25.2V | 500ns | - | 48mA | - | -40°C ~ 85°C | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP14TRANSDUCER |
3,740 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | 1000A | DC ~ 150kHz | ±0.1% | ±0.5% | ±24V | 1µs | - | - | - | -40°C ~ 85°C | Bidirectional | Chassis Mount | - |
|
IVT-S-300-U0-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
3,994 |
|
Datasheet |
IVT-S | Module | Tray | Active | DC | Shunt | - | CAN Bus | - | 300A | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | - | 80mA | - | -40°C ~ 105°C | Bidirectional | Chassis Mount | - |